access_control [2024-03-23 12:11] – [Device Issues] timaccess_control [2024-04-16 21:11] tim
Line 24: Line 24:
   * we should replace power supplies and/or deploy ESP32 devices   * we should replace power supplies and/or deploy ESP32 devices
  
-Tool controller PCBs: new tool controller PCBs are available and need to be assembled. There are 2 fully assembled and another with SMD components only.+Tool controller PCBs: new tool controller PCBs are available and need to be assembled. There is one fully assembled and another three with SMD components only. Two more D1 Minis are required.
  
 Documentation: Documentation:
Line 43: Line 43:
 Migrate firmware config files to proper "/" prefix. Migrate firmware config files to proper "/" prefix.
  
-Purchase more PN532 NFC modules from elechouse.com and few of the new PN7150 for development. [ordered, in transit] +<del>Purchase more PN532 NFC modules from elechouse.com and few of the new PN7150 for development. [ordered, in transit]</del>
 ===== Device Issues ===== ===== Device Issues =====
  
Line 55: Line 54:
   * approx 300W   * approx 300W
   * 2024-03-15: suppression capacitor fitted, appears to work   * 2024-03-15: suppression capacitor fitted, appears to work
 +  * 2024-04-09: bypass removed
  
 Welder: Welder:
-  * poor connectivity, repeated reconnects+  * poor connectivity, repeated reconnects - fixed by channel change?
   * crashes when welder is in use   * crashes when welder is in use
   * LCD sometimes shows corruption when welder is in use   * LCD sometimes shows corruption when welder is in use
 +  * 2024-04-13: suppression capacitor fitted to contactor, prevents crashing at power-off
  
 Bandsaw: Bandsaw:
-  * poor connectivity, repeated reconnects+  * poor connectivity, repeated reconnects - fixed by channel change?
  
 Mitre saw: Mitre saw:
   * poor connectivity, repeated reconnects   * poor connectivity, repeated reconnects
   * replacing the controller didn't help   * replacing the controller didn't help
-  * 2024-03-21: replaced PSU with Mean Well+  * 2024-03-21: replaced PSU with Mean Well, has not helped 
 +  * 2024-03-24: firmware update failed repeatedly over 4 hours, device moved to G1 and it succeeded immediately, moved back to g8 and connectivity went bad again. 
 +  * 2024-03-28: changing channel (11->6) on unifi-g8 has helped
  
 Big laser cutter: Big laser cutter:
Line 88: Line 91:
 CNC router: CNC router:
   * corrupted LCD   * corrupted LCD
 +  * microcontroller crash and monitor blanks when contactor switches off
 +    * 2024-04-16: added capacitor to contactor coil
  