Line 132: Line 132:
 Cable colours in Hacklab installations: Cable colours in Hacklab installations:
  
-^ Pin ^ G1/G2/G8 ^ G11 (and photos) ^ +^ Pin ^ G1/G2/G8 ^ G11 (and photos) ^ Alarm Wire 
-| GND | blue | blue | +| GND | blue | blue | black 
-| VCC | green | orange | +| VCC | green | orange | red 
-| RST | brown | brown +| SDA | orange | green | yellow 
-| SDA | orange | green | +| SCL | white-green | white-green | blue | 
-| SCL | white-green | white-green | +| RST | brown | brown | green | 
-| LED +ve | white-brown | white-brown | +| LED +ve | white-brown | white-brown | orange 
-| Piezo | white-blue | white-blue |+| Piezo | white-blue | white-blue | white |
  
 The LED should be connected between LED and GND, with a 120R series resistor. To avoid damaging the LED, use hot-melt glue to secure it in place (not cyanoacrylate). The LED should be connected between LED and GND, with a 120R series resistor. To avoid damaging the LED, use hot-melt glue to secure it in place (not cyanoacrylate).