door_access_controllers [2019-04-29 17:50] timdoor_access_controllers [2019-09-22 22:08] tim
Line 5: Line 5:
 The Hacklab door controllers are based on an ESP8266 wifi microcontroller and a PN532 NFC reader module. One controller is installed for each door, and each controller can operate a single 12V channel for an electric door release or magnetic lock. Inputs can be connected for door open/closed reed switch, exit request and local lock/unlock "snib" function. The Hacklab door controllers are based on an ESP8266 wifi microcontroller and a PN532 NFC reader module. One controller is installed for each door, and each controller can operate a single 12V channel for an electric door release or magnetic lock. Inputs can be connected for door open/closed reed switch, exit request and local lock/unlock "snib" function.
  
-===== PCB =====+===== PCB v2 =====
  
-https://github.com/timhawes/onyx_robot/+https://github.com/timhawes/onyx_robot/tree/or2
  
 ^ Reference ^ Component ^ Farnell ^ ^ Reference ^ Component ^ Farnell ^
Line 33: Line 33:
 Errata: a generic through-hole flyback diode should be fitted between GND and 12V_OUT, on the underside of the screw terminal. Errata: a generic through-hole flyback diode should be fitted between GND and 12V_OUT, on the underside of the screw terminal.
  
-==== Lessons Learned ====+==== PCB v3 ==== 
 + 
 +  * Off-the-shelf DC-DC converter instead of custom circuit 
 +  * Split voltages 5V (for piezo and NFC module) and 3.3V for ESP8266 
 +  * Flyback diode on 12V switched output 
 +  * TVS diodes removed 
 +  * Normally-closed relay option removed 
 +  * Pull-up removed from piezo 
 + 
 +==== Future ==== 
 + 
 +Future versions may use the Wemos D1 Mini to aid maintainability. Alternatively, the next design may use the more powerful ESP32. 
  
-Future PCB revisions are likely to be based on a Wemos D1 Mini module to reduce component count and allow easier debugging. The onboard DC-DC converter will be replaced with an off-the-shelf "LDO replacement" DC-DC converter module. 
 ===== Controller Unit ===== ===== Controller Unit =====
  
Line 109: Line 119:
 ===== Software ===== ===== Software =====
  
-Two versions of firmware and server back-end are currently in operation. +Features:
- +
-Common features:+
  
   * Ability to read any 13.54MHz ISO-14443 Type A token including MIFARE Classic/UltraLight and NFC tags.   * Ability to read any 13.54MHz ISO-14443 Type A token including MIFARE Classic/UltraLight and NFC tags.
Line 121: Line 129:
   * Remote enable/disable/renewal/timeout of snib state to allow presence detection to trigger timeout of snib state.   * Remote enable/disable/renewal/timeout of snib state to allow presence detection to trigger timeout of snib state.
   * Input DC voltage measurement, using low voltage as an indication of battery backup during a power outage. Snib feature can be disabled during power outage to extend battery life (for fail-secure locks).   * Input DC voltage measurement, using low voltage as an indication of battery backup during a power outage. Snib feature can be disabled during power outage to extend battery life (for fail-secure locks).
- +  * TLS-enabled TCP networking with OTA updates.
-Legacy/Stable: The older version uses UDP networking and requires a dedicated wifi network for security. All of the Hacklab doors use this version at the time of writing. +
- +
-New: A new firmware and back-end use TLS-enabled TCP networking, so do not require a special wifi network. The modern codebase is better-written, more flexible and features OTA upgrades.+
  
door_access_controllers.txt · Last modified: 2023-04-08 10:24 by tim