 ==== Some Notes ==== ==== Some Notes ====
   * Password for switching to management mode is ...... (6 periods)   * Password for switching to management mode is ...... (6 periods)
-  * yaskawa mode: [[industrialrobotarm:private]]+  * yaskawa mode: [[private:industrialrobotarm|password]]
   * Gripper (DC motor with a simple on-off controller) controls:   * Gripper (DC motor with a simple on-off controller) controls:
  
Line 105: Line 105:
  
  
 +==== Remote mode ====
 +  * Select "In/out" -> "Remote" to view current status:
 +    * Not specified: read-only
 +    * I/O mode: partial write access?
 +    * Command and I/O mode: full write access
 +  * The "remote" light must be on for remote access
 +  * The "play" light must also be on for full write access
  
 +=== Configuration ===
 +  * Set parameter RS005:
 +    * 0: remote mode read/write allowed
 +    * 1: remote mode is read-only
 +  * Set "In/out" -> "pseudo input signal" as follows, pressing Interlock and Select together to toggle an option:
 +    * #8214 INHIBIT IO
 +      * 0: remote access disabled
 +      * 1: remote access enabled
 +    * #8215 CMD REMOTE SEL
 +      * 0: disable command mode
 +      * 1: enable command mode
 +    * #8216 INHIBIT PP/PANEL
 +      * 0: pendant is allowed to move the robot while in remote command mode
 +      * 1: pendant is not allowed to move the robot while in remote command mode
 +      * e-stop is always available