tool_access_controllers [2024-11-04 22:09] – [Enclosure and Wiring] timtool_access_controllers [2024-11-04 22:10] (current) – [Enclosure and Wiring] tim
Line 94: Line 94:
 More complex tools may have their own control systems (remote start/stop, VFD motor controllers, etc). In these cases we may fit our relay to the incoming contactor or to the control signals loop or to the estop/interlock loop. More complex tools may have their own control systems (remote start/stop, VFD motor controllers, etc). In these cases we may fit our relay to the incoming contactor or to the control signals loop or to the estop/interlock loop.
  
-**Noise suppression:**+==== Noise suppression ====
  
 Some motors and contactors will create electrical noise, causing the microcontroller to crash or reset. If this happens the noise should be suppressed at source. A 0.1uF or 0.22uF class X2 capacitor (fitted across live and neutral close to the source) will often resolve the issue. Some motors and contactors will create electrical noise, causing the microcontroller to crash or reset. If this happens the noise should be suppressed at source. A 0.1uF or 0.22uF class X2 capacitor (fitted across live and neutral close to the source) will often resolve the issue.
tool_access_controllers.1730758177.txt.gz · Last modified: 2024-11-04 22:09 by tim