Line 217: | Line 217: | ||
An additional relay is fitted in the laser cutter chassis. The relay' | An additional relay is fitted in the laser cutter chassis. The relay' | ||
- | A laser activity monitor is fitted to give the tool controller visibility of actual laser firing. The 5V control input on the high voltage laser PSU is connected, via an optocoupler, | + | A laser activity monitor is fitted to give the tool controller visibility of actual laser firing. The 5V control input on the high voltage laser PSU is connected, via an optocoupler, |
{{: | {{: | ||
Line 225: | Line 225: | ||
{{:: | {{:: | ||
- | Laser activity monitoring | + | Since the photos were taken the optocoupler 5V input is now taken from the laser cutter' |
+ | |||
+ | Note that the tool controller will also detect an active state based on **attempted** firing of the laser. For example, if the lid is opened during a job the laser will be disabled but the time will still be counted. | ||
+ | |||
+ | The software is still in an inconsistent state. The laser activity time is displayed on the LCD, and it is used to detect | ||
Additional monitoring could be added in future: | Additional monitoring could be added in future: | ||
Line 310: | Line 314: | ||
2025-05-31: | 2025-05-31: | ||
- | * Active time monitoring connected to the tool controller | + | * Active time monitoring connected to the tool controller |
* Guide laser ground wire was broken in two places, repaired and aligned | * Guide laser ground wire was broken in two places, repaired and aligned | ||
+ | |||
+ | 2025-06-13: | ||
+ | * Guide laser doesn' | ||